Bathroom Extract Fans

In-line Duct Fans

Central exhaust fans

Central systems

Decentralized systems

Brofer Pura accessories

Ventilators

Dehumidifiers

Humidifiers

Air purifiers

Hair dryers

Heating

Kitchen hoods

Built-in duct fans

Fans in acoustic cabinets

Fans for installation on the roof

Compact devices

Modular devices

Fire dampers

Smoke exhaust flaps

Air curtains

Grids

Diffusers

Regulation

Insulation

Slovenščina (Slovenija)Slovenščina (Slovenija)
Slovenščina (Slovenija)Slovenščina (Slovenija)
English (United Kingdom)English (United Kingdom)

CADB/T-HE BASIC

Heat recovery units with high-efficiency counterflow plate heat exchanger (up to 93%), certified by Eurovent, mounted in a galvanised steel double-walled enclosure with internal thermo-acoustic insulation (A1/M0) made of 25mm thick mineral wool in models 04 to 33 and 47mm in models 45 to 100.Adjustable input and output ports, versions for horizontal and vertical installation.Minimum outside air temperature -10ºC.
Deli
For lower temperatures it is necessary to use preheating coils located in the external air inlet.ApplicationsCommercial premises, offices, hospitality venues, public buildings, schools.The CADB/T-HE-D BASIC range is not available with additional post-heating coils.The BASIC control does not support the control of external heating or cooling coils.Without additional heating input.MotorsModels 04 to 33: Single-phase EC motors with integrated electronic protection. IP44, Type B.Models 45 to 100: EC motors with three-phase supply, with integrated electronic protection, IP54, Class B.FansPlug fans with reverse impeller blades.Filters- F7: Low-loss F7 filters (ePM1 70%) for air supply.- M5: M5 filters (ePM10 50%) for air extraction.- It is possible to install a second filter inside the system (supplied as an accessory).ControlIt includes an integral operation control, located inside the unit and wired to all the components (fans, bypass, filter clogging detectors, temperature probes, etc.).It allows manual or automatic fan control.It allows two possible automatic fan control modes:VAV- Variable Air Volume: Fan speed can be adjusted using a 0 - 10V analogue signal from the remote touchscreen panel (included) or an external CO2 sensor (accessories).COP - Constant Pressure (only available via Modbus): The fan speed is regulated to maintain a constant pressure in the duct network.A TDP-D pressure sensor is necessary (accessory).This function cannot be activated with the remote control supplied with the unit.Other DataSingle-phase (CADB-HE BASIC) and three-phase (CADT-HE BASIC) models.Nominal flow rates from 450 to 10,000 m3/h. All models and versions include internal bypass.Interchangeable side panels allowing multiple orientations of air inlets and outlets.
installation CADB/T-HE BASIC